Authorized Distributor Worldwide Distribution Competitive Prices Fast Shipping from Germany
11 manufacturers
All Manufacturers More Manufacturers on Request

2905011 - QUINT-PS/60-72DC/24DC/10/CO – Phoenix Contact

GTIN / EAN: 4046356908320 Part Number: 2905011 Part Type: QUINT-PS/60-72DC/24DC/10/CO Manufacturer: Phoenix Contact DC/DC converter, protective coating
Part Number
2905011 - QUINT-PS/60-72DC/24DC/10/CO
Availability
Available
Description
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (Selective Fuse Breaking) technology, input: 60-72 V DC, output 24 V DC / 10 A
Product type DC/DC converters
Connection method Screw connection
Colour green, yellow
Degree of protection IP20
Mounting type DIN rail: 35 mm
Conductor cross-section, rigid min. 0.2 mm²
Data Sheet Download

Technical Data

187 values
Input data (14)

DC operation

Nominal input voltage range 60 V DC ... 72 V DC
Input voltage range 42 V DC ... 96 V DC
Wide-range input Yes
Input voltage range DC 42 V DC ... 96 V DC
Voltage type of supply voltage DC
Inrush current ≤ 9 A
Inrush current integral (I2t) 0.64 A2s
Mains buffering time typ. 10 ms (60 V DC)
Current consumption 5.6 A, 4.7 A
Reverse polarity protection , ≤ 30 V DC
Nominal power consumption 268 VA
Protective circuit Transient surge protection; Varistor
Input fuse 10 A 150 V DC (internal (device protection))
Output data (41)
Efficiency ≥ 91 %
Output characteristic U/I
Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 10 A
POWER BOOST (IBoost) 12.5 A
Selective Fuse Breaking (ISFB) 60 A
Magnetic circuit breaker tripping B2 / B4 / B6
Derating 60 … 70 °C
Feedback voltage resistance 35 V
Protection against overvoltage at the output (OVP) ≤ 35 V
Max. capacitive load unlimited
Active current limitation 18 A
Control deviation ≤ 1 %, ≤ 2 %, ≤ 0.1 %
Residual ripple ≤ 20 mVPP
Short-circuit-proof Yes
Output power 240 W
Peak switching voltages nominal load ≤ 10 mVPP
Maximum no-load power dissipation 4 W
Power loss nominal load max. 24 W
Rise time < 2 ms (UOUT (10 % ... 90 %))
Connection in parallel yes, for redundancy and increased capacity
Connection in series Yes
Fuse protection (secondary side) electronic, thermal-magnetic, thermal

Signal: DC OK active

Output description UOUT > 0.9 x UN: High signal
Switching voltage range 18 V DC ... 24 V DC
Maximum inrush current ≤ 20 mA

Signal: POWER BOOST, active

Output description IOUT < IN: High signal
Switching voltage range 18 V DC ... 24 V DC
Maximum inrush current ≤ 20 mA

Signal: UIN OK, active

Output description UIN > 19.2 V: High signal
Switching voltage range 18 V DC ... 24 V DC
Maximum inrush current ≤ 20 mA

Signal: DC OK floating

Output description Relay
Output voltage ≤ 30 V
Maximum inrush current ≤ 100 mA
Connection data (31)

Input

Connection method Screw connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 2.5 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 2.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 12
Stripping length 8 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

Output

Connection method Screw connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 2.5 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 2.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 12
Stripping length 7 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

Signal

Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 2.5 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 2.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 12
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signaling (12)
Types of signaling LED, Active switching output, Relay contact

Signal output: DC OK active

Status display "DC OK" LED green
Colour green

Signal output: POWER BOOST, active

Status display "BOOST" LED yellow/IOUT > IN : LED on
Colour yellow
Note on status display LED on

Signal output: UIN OK, active

Status display LED "UIN < 0.8 x UN V" yellow/UIN < 0.8 x UN V DC: LED on
Colour yellow
Note on status display LED on

Signal output: DC OK floating

Note on status display UOUT > 0.9 x UN: Contact closed
Electrical properties (4)
Number of phases 1
Insulation voltage input/output 1.5 kV, 1 kV
Product properties (6)
Product type DC/DC converters
Product family QUINT POWER
MTBF (IEC 61709, SN 29500) ≥ 1,349,000 h, ≥ 765,000 h

Insulation characteristics

Protection class I
Degree of pollution 2
Dimensions (10)
Width 48 mm
Height 130 mm
Depth 125 mm

Installation dimensions

Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)

Alternative assembly

Width 122 mm
Height 130 mm
Depth 51 mm
Mounting (4)
Mounting type DIN rail: 35 mm
Assembly note alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN
Mounting position horizontal DIN rail NS 35, EN 60715
With protective coating Yes
Material specifications (3)
Housing material Metal
Type of housing Aluminum (AlMg3)
Hood version Galvanized sheet steel, free from chrome (VI)
Environmental and real-life conditions (10)

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 … 70 °C
Ambient temperature (storage/transport) -40 … 85 °C
Ambient temperature (start-up type tested) -40 °C
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) 100 %
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6), 15 Hz ... 150 Hz, 2.3g, 90 min.
Temp code T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K)
Standards and regulations (10)
Rail applications EN 50121-4, EN 50155
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Safety extra-low voltage EN 60950-1 (SELV), EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Noxious gas test ISA-S71.04-1985 G3 Harsh Group A

Fire protection in rail vehicles

Standard designation Fire protection in rail vehicles
Standards/specifications EN 45545-2 (HL3)
Approvals (3)
UL approvals UL/C-UL listed UL 508, UL/C-UL Recognized UL 60950-1, UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
EMC data (39)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
EMC requirements for noise emission EN 61000-6-3, EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1, EN 61000-6-2

Electrostatic discharge

Standards/regulations EN 61000-4-2
Contact discharge 8 kV
Discharge in air 15 kV
Comments Criterion A

Electromagnetic HF field

Standards/regulations EN 61000-4-3
Frequency range 1 … 80 GHz, 1 … 2 GHz, 2 … 3 GHz
Test field strength 20 V/m, 10 V/m
Comments Criterion A

Fast transients (burst)

Standards/regulations EN 61000-4-4
Input 4 kV
Output 2 kV
Signal 2 kV
Comments Criterion A

Surge voltage load (surge)

Standards/regulations EN 61000-4-5
Input 2 kV, 4 kV
Output 1 kV, 2 kV
Signal 1 kV
Comments Criterion A

Conducted interference

Standards/regulations EN 61000-4-6
Input/output/signal asymmetrical
Frequency range 9 … 80 MHz
Comments Criterion A
Voltage 10 V

Emitted interference

Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Commercial Data

Packing Unit 1
Minimum Order Quantity 1
Unit of Measure pcs
Net Weight 1,190 g
Gross Weight 1,166 g
Dimensions (H × W × D) 80 × 80 × 180 mm
Country of Origin CN
Customs Tariff Number 85044095
RoHS Compliant Yes
ECCN N
Export List Number DE N
Packing Type CT
Package Can Be Opened Yes
Production Type From Stock
Product group Power Supply Units
ETIM Class EC002540
eCl@ss 27040701

Approvals

6 approvals
  • cUL Recognized
    Certificate E211944
  • UL Recognized
    Certificate E211944
  • UL Listed
    Certificate E123528
  • cUL Listed
    Certificate E123528
  • CoC / Compliance Statement
    Certificate 18-050-00
  • cUL Listed
    Certificate E199827

Downloads

1 file
Data Sheet 206 KB Download

Accessories

10 products

UTA 107/30

Part Number 2320089

UWA 182/52

Part Number 2938235

Similar Products

8 products
Copied
Added to the Inquiry List · Part Number
Back to top